Commercial Propane Tank Sizes

Get a Free Quote Today

Avenir provides a wide range of propane tank sizes to match the energy needs of any business. The right size and number of tanks depends on several factors — BTU load, usage patterns, delivery frequency, property spacing, and local regulations. Getting this right the first time matters: an undersized tank or a poorly planned install creates a supply risk down the road, not just an inconvenience. Avenir helps determine the correct size and placement for each site, with installations that meet all local and national codes.

Propane Tank Sizes

66ec5c9f7848b14776df7a96 propane tank measurements 420lb (1)

420 lb. tank

Dimensions
4’5” in height and 30” in diameter
 
Capacity
363 L per tank
 
Uses
Well suited to cooking and heating for smaller buildings with tight spacing.
 
Spacing
Can be placed against the building, and up to 4 tanks can be tied together. Must be installed 10 feet from sources of electricity.
66ec5c9e2872ab7a124db11c propane tank measurements 500gal (1)

500-gallon tank

Dimensions
10’1” in length, 4’ in height and 38” in diameter
 
Capacity
1514 L per tank
 
Uses
Well suited to temporary heating, cooking, and a variety of agricultural applications.
 
Spacing
Must be located 10 feet from any building, property line, and source of electricity. Trenching is required to run gas lines from the tank to the building.
66ec5c9e8a0d07718f059c1c propane tank measurements 1000gal (1)

1000-gallon tank

Dimensions
15’11” in length, 4’4” in height and 41” in diameter
 
Capacity
3028 L per tank
 
Uses
Sized for larger commercial appliances and agricultural operations with high use and BTU loads.
 
Spacing
Must be located 10 feet from any building, property line, and source of electricity. Trenching is required to run gas lines from the tank to the building.
66ec5c9e0b1e933efd1f3cf8 propane tank measurements 2000gal

2000-gallon tank

Dimensions
22’8” in length, 4’10” in height and 48” in diameter
 
Capacity
6435 L per tank
 
Uses
 Built for large-scale industrial facilities and agricultural operations such as crop drying.
 
Spacing
Must be located 25 feet from any building, and 10 feet from any property line and source of electricity. Trenching is required to run gas lines from the tank to the building.
67ffa71a6ce08607ff38b4d0 propane tank measurements 1000 vertical

1000-gallon vertical tank

Dimensions
18’ in height, 40.5” in diameter and 48” base
 
Capacity
3028 L per tank
 
Uses
Suited to larger commercial appliances with high use and BTU loads where ground spacing is limited.
 
Spacing
Must be located 10 feet from any building, property line, and source of electricity. Trenching is required to run gas lines from the tank to the building.
67ffa93a71dab2f3977024ac propane tank measurements 2000 vertical

2000-gallon vertical tank

Dimensions
22’8” in length, 4’10” in height and 48” in diameter
 
Capacity
6435 L per tank
 
Uses
Built for large-scale industrial facilities and agricultural operations such as crop drying.  
 
Spacing
Must be located 25 feet from any building, and 10 feet from any property line and source of electricity. Trenching is required to run gas lines from the tank to the building.

Propane Safety

Safe operation is the standard Avenir holds every commercial installation to. Propane is one of the safest fuels available when it’s sized, installed, and maintained correctly, which is why only a qualified propane technician should ever service tanks or appliances. Never attempt repairs without a technician. Avenir will send a qualified technician to assess the situation.

Detecting a Propane Leak

Propane is treated with mercaptan, giving it a distinct “rotten egg” smell that makes a leak easy to identify quickly. If that smell is present, here’s exactly what to do:

66eacbfb0cd2bcf485913a75 safety leave

Don’t Panic

Leave the area immediately in an orderly manner if you suspect a propane leak.

Image

Shut Off the Propane Supply

Turn off the tank supply by turning the handwheel clockwise (to the right) as far as possible unless the leak appears to be coming from that area.

66eacbfbcca10b3b39833313 safety no flames

Avoid Flames, Sparks and Electricity

Extinguish flames and do not use lights, appliances or phones.

66eacbfbebdc28cf66ec67c7 safety call help

Call for Help

Contact the fire department or dial 911 from a safe distance (at least 20 ft from the source of the leak).

Do not re-enter the area until it is deemed safe. Contact Avenir Energy to have a technician turn the propane back on to check and re-light your appliances.  

Propane Appliance Safety

Regular Maintenance

Regular inspection by a qualified Avenir technician keeps propane appliances and tanks operating as they should. The 24ProPlus™ Plan is available for businesses that want that maintenance scheduled automatically rather than tracked manually.

Know the Signs

Propane should always burn clean with a blue flame. Yellow or irregular flames, or soot around an appliance, are signs the propane isn't burning properly and could allow carbon monoxide to be released.

Install Detectors

Carbon monoxide detectors placed near propane appliances monitor air quality and provide an early alert in the event of a leak. If a detector activates, the property should be vacated immediately and 911 contacted.

Ventilation is Key

All appliances should be properly vented to the outside to prevent carbon monoxide buildup. Outdoor propane appliances, such as grills and generators, should never be used indoors or in an enclosed space.

Winter safety avi

Storm Safety

Before the Storm

Debris cleared from around the tank helps prevent damage during severe weather.

After the Storm

Tanks and appliances should be inspected for any signs of damage, and a clear path to propane tanks should be kept open through the winter months so nothing slows down a delivery when it’s needed.

Commercial Propane Tank Questions, Answered

Avenir installs six commercial formats: a 420 lb tank at 363 L, a 500 gallon at 1,514 L, a 1000 gallon at 3,028 L and a 2000 gallon at 6,435 L, plus vertical versions of the 1000 and 2000 gallon for sites where ground space is limited. Residential sizes are covered on the residential propane tanks page.

10 feet 1 inch long, 4 feet high and 38 inches in diameter, holding 1,514 L. It must sit 10 feet from any building, property line and source of electricity, and trenching is required to run the line to the appliance.

15 feet 11 inches long, 4 feet 4 inches high and 41 inches in diameter, holding 3,028 L. The vertical version holds the same 3,028 L but stands 18 feet high on a 48 inch base with a 40.5 inch diameter, which suits a yard that cannot give up the horizontal run.

Yes, and it is the largest format Avenir installs. It measures 22 feet 8 inches long, 4 feet 10 inches high and 48 inches in diameter, holding 6,435 L. It is built for large industrial facilities and agricultural operations such as crop drying, and it needs 25 feet of clearance from any building rather than the usual 10.

363 L. It stands 4 feet 5 inches high and is 30 inches in diameter. It is the only format that can be placed against a building, and up to four can be tied together to add capacity without taking more ground.

Clearance is the rule that decides most installations. Commercial tanks must sit 10 feet from any building, property line and source of electricity, and a 2000 gallon tank needs 25 feet from a building. Trenching is required to run the gas line. The 420 lb tank is the exception and may go against the wall. Installation is done by a certified technician.

Avenir logo dark

Canada’s Local Propane Supplier for Delivery and Refills

Copyright © All rights reserved. Privacy Policy